logo
Bericht versturen
producten
DETAILS VAN DE PRODUCTEN
Huis > Producten >
High and Low Temperature Humidity Test Chamber with 1000 L Volume 1000 mm×1000 mm×1000 mm Inner Box Size and 480 V Power Supply

High and Low Temperature Humidity Test Chamber with 1000 L Volume 1000 mm×1000 mm×1000 mm Inner Box Size and 480 V Power Supply

MOQ: 1
Prijs: To be quoted
Standaardverpakking: Veiligheidskartonpakket of multiplexbox
Betalingswijze: T/T
Gedetailleerde informatie
Plaats van herkomst
CHINA
Merknaam
Kingpo
Certificering
ISO 17025
Modelnummer
RSR1000-040PFE
Volume testkamer:
1000 L
Grootte van de binnenkast:
1000 mm×1000 mm×1000 mm (B×H×D)
Markeren:

1000 L Volume Temperature Humidity Chamber

,

1000 mm×1000 mm×1000 mm Inner Box Size Test Chamber

,

480 V Power Supply Environmental Test Chamber

Productbeschrijving
High and Low Temperature Humidity Test Chamber
Instrument Specifications
Specification Details
Product Name High and Low Temperature Humidity Test Chamber
Instrument Model RSR1000-040PFE
Factory Number SHS20252072
Production Date 20250820
Test Chamber Volume 1000 L
Inner Box Size 1000 mm × 1000 mm × 1000 mm (W×H×D)
Outer Box Size 1275 mm × 2110 mm × 2100 mm (W×H×D)
Power Supply Voltage AC 480 V 60 Hz three phase five wire
Standard Accessories
  • One test chamber
  • Power cord (extending 5 meters outside the device)
  • Two silicone soft plugs (for test holes)
  • Test specimen shelf with two layers
  • Two sets of shelf hooks
  • Special wet ball gauze (five strips)
  • Operating instructions
  • Certificate of conformity and warranty card
Main Technical Parameters
Temperature Parameters
Parameter Value
Temperature Range -40℃ to 150℃
Temperature Fluctuation ≤ ±0.5℃
Temperature Deviation ≤ ±2.0℃
Temperature Uniformity ≤2.0℃
Cooling Rate ≥1.0℃/MIN
Heating Rate ≥2.9℃/MIN
Humidity Parameters
Parameter Value
Humidity Range 10% RH to 98% RH
Temperature Range of Controlled Humidity 10℃ to 90℃
Humidity Deviation ≤ ±2.0%RH
Note: The above parameters are measured under ambient temperature 25℃, relative humidity ≤85%RH, no heat source around, and no load in the test area.
Load Specifications
  • Heat Source Load: No load
  • Specimen Load: No load
High and Low Temperature Humidity Test Chamber with 1000 L Volume 1000 mm×1000 mm×1000 mm Inner Box Size and 480 V Power Supply 0
Usage Environment Requirements
  • Ambient temperature: 5℃-35℃
  • Relative humidity: ≯85%RH
  • Atmospheric pressure: 80kPa-106kPa
  • Reserved space: ≮2 meters in front, ≮1 meter in the back and sides, ≮0.5 meters at the top
  • Wastewater discharge: Drainage device or collection box within one meter from rear
  • Keep away from direct sunlight, with smooth airflow, no strong vibration, heat sources, or high-concentration dust/flammable gases
Aanbevolen producten
producten
DETAILS VAN DE PRODUCTEN
High and Low Temperature Humidity Test Chamber with 1000 L Volume 1000 mm×1000 mm×1000 mm Inner Box Size and 480 V Power Supply
MOQ: 1
Prijs: To be quoted
Standaardverpakking: Veiligheidskartonpakket of multiplexbox
Betalingswijze: T/T
Gedetailleerde informatie
Plaats van herkomst
CHINA
Merknaam
Kingpo
Certificering
ISO 17025
Modelnummer
RSR1000-040PFE
Volume testkamer:
1000 L
Grootte van de binnenkast:
1000 mm×1000 mm×1000 mm (B×H×D)
Min. bestelaantal:
1
Prijs:
To be quoted
Verpakking Details:
Veiligheidskartonpakket of multiplexbox
Betalingscondities:
T/T
Markeren

1000 L Volume Temperature Humidity Chamber

,

1000 mm×1000 mm×1000 mm Inner Box Size Test Chamber

,

480 V Power Supply Environmental Test Chamber

Productbeschrijving
High and Low Temperature Humidity Test Chamber
Instrument Specifications
Specification Details
Product Name High and Low Temperature Humidity Test Chamber
Instrument Model RSR1000-040PFE
Factory Number SHS20252072
Production Date 20250820
Test Chamber Volume 1000 L
Inner Box Size 1000 mm × 1000 mm × 1000 mm (W×H×D)
Outer Box Size 1275 mm × 2110 mm × 2100 mm (W×H×D)
Power Supply Voltage AC 480 V 60 Hz three phase five wire
Standard Accessories
  • One test chamber
  • Power cord (extending 5 meters outside the device)
  • Two silicone soft plugs (for test holes)
  • Test specimen shelf with two layers
  • Two sets of shelf hooks
  • Special wet ball gauze (five strips)
  • Operating instructions
  • Certificate of conformity and warranty card
Main Technical Parameters
Temperature Parameters
Parameter Value
Temperature Range -40℃ to 150℃
Temperature Fluctuation ≤ ±0.5℃
Temperature Deviation ≤ ±2.0℃
Temperature Uniformity ≤2.0℃
Cooling Rate ≥1.0℃/MIN
Heating Rate ≥2.9℃/MIN
Humidity Parameters
Parameter Value
Humidity Range 10% RH to 98% RH
Temperature Range of Controlled Humidity 10℃ to 90℃
Humidity Deviation ≤ ±2.0%RH
Note: The above parameters are measured under ambient temperature 25℃, relative humidity ≤85%RH, no heat source around, and no load in the test area.
Load Specifications
  • Heat Source Load: No load
  • Specimen Load: No load
High and Low Temperature Humidity Test Chamber with 1000 L Volume 1000 mm×1000 mm×1000 mm Inner Box Size and 480 V Power Supply 0
Usage Environment Requirements
  • Ambient temperature: 5℃-35℃
  • Relative humidity: ≯85%RH
  • Atmospheric pressure: 80kPa-106kPa
  • Reserved space: ≮2 meters in front, ≮1 meter in the back and sides, ≮0.5 meters at the top
  • Wastewater discharge: Drainage device or collection box within one meter from rear
  • Keep away from direct sunlight, with smooth airflow, no strong vibration, heat sources, or high-concentration dust/flammable gases